Electrical installations

PROTECT STATUS: not protected
Longread translated automatically

EXCESSIVES

big
Original size 917x502

TRAFFIC AND TRAFFIC TRAFFIC

big
Original size 594x305

PROGRAMMED OUTLINES AND TERMS OF REFERENCE

big
Original size 633x281

EXAMPLES OF THE APPLICATION OF ONE-OPERATING REPRESENTATIVES

Original size 629x329

EXAMPLES OF THE APPLICATION OF TWO-CLAIMANTS

Original size 716x454

THREE CLAIMANTS AND OTHER MECHANISMS

The power switches of the modular series consist of the framework and the mechanism itself. There are two types of modular series: German and Italian. By the German standard, the frame is divided by links, within which two switches are placed. Such modules can be installed both vertically and horizontally. The modules are more compact by the Italian standard, because they don’t share the links. But they can only be set horizontally.

Original size 1148x406
Original size 764x593
Original size 854x644

CLASSIFICATIONS OF ELECTRIC POSETS/ CONCLUDANTS

GOST 21.210-2014 Project document system for the construction of CLECTRONIC ELECTRIC DISTRIBUTIONS AND PRODUCTS ON PLANS

CLIMATE MARKINGS OF LIGHTS/ROZENES EVENTLY USED IN DIESIN PROJECTS

CLIMATE MARKINGS OF CLAIMANTS

CLIMATE MARKINGS

Number of outlets and power grid phases

If the bar is parallel, the number determines the number of points in the outlet (one, two, three and four) for a single phase power grid. These are the most common options in the accommodation and office arrangements. One phase is 220 volts. If the strokes are located by a semi-star, then the outlet is three-phase (380 volts). The number of seats is always the same. Such symbols are used in accommodations to indicate electrical connection outlets, as well as in drawings of industrial buildings and facilities where the equipment is used.

Method of installation of the outlet and its IP (protection level)

Water supply outlets: A special lid shall be installed to protect contact from water contamination. Level of protection against IP 44. The first number means the degree of protection against dust and fine particles. It’s going to be 0 to 6. 0 is not protected from dust and particles; 1 is protected from dust particles larger than 50 millimeters; 2 is protected from dust particles larger than 12 millimeters; 3 is protected from dust particles larger than 2.5 millimeters; 4 is protected from dust particles larger than 1 millimeter; 5 is very secure from dust; and 6 is completely protected from dust of different sizes. Number two. indicates the level of protection of the outlet against moisture. Maybe between 0 and 8. 0 — there is no protection against moisture; 1 — protection against vertical drops of water; 2 — protection against droplets falling at an angle of 15 degrees; 3 — protection against drops of moisture that can fall at an angle of 60 degrees; 4 — protection against spray of water; 5 — protection against jets of water; 6 — protection against high water jets; 7 — protection against short-term flooding into water; 8 — safety against long-term flooding into water. In the normal spaces, outlets with IP20 security. In bathrooms, in rooms with an IP44 security outlet pool. There are outlets with IP65 and above on the street. In the bathrooms, outlets with integrated ultrasound should be installed. Receptacles with protective curtains equipped with a protective deactivation function. The power shall be switched off automatically when a dangerous current leak is detected.

Electrical installations